VAERS Explorer
Back to explore

Report #2893498

Received Apr 21, 2026

A note on interpretation. VAERS reports are unverified and may be incomplete or coincidental. A report does not establish that a vaccine caused an event, and counts should not be used to calculate incidence or infer causation. Full disclaimer

Overview

Sex
Male
Age
46 yrs
State
Recovered
Unknown
Vaccinated
Sep 19, 2025
Onset
Sep 19, 2025
Days to onset
0
Hospital days

Vaccines (1)

TypeNameManufacturerDoseLotRoute / Site
UNKVACCINE NOT SPECIFIED (NO BRAND NAME)UNKNOWN MANUFACTURERUNK4n222

Symptoms (1)

Product preparation issue

Symptom narrative

While checking on-hand inventory for Priorix on [date discovered] due to a scheduled administration, an additional vial of Priorix powder was identified. This prompted a review of recent administration records and available camera footage. Upon review, it was observed that on 09/19/2025, a patient presented for three vaccinations, one of which included Priorix. Camera footage shows the pharmacist retrieving three vaccines; however, no separate vial required to reconstitute the Priorix with diluent was retrieved. The pharmacist then attached three needles to the vaccine syringe barrels and entered the immunization room. This finding suggests the possibility that Priorix may not have been properly reconstituted prior to administration.